BITZER GROUP LODAM OLC-K1 TECHNICAL MANUAL Pdf Download (2024)

BITZER GROUP LODAM OLC-K1 TECHNICAL MANUAL Pdf Download (1)
  1. Manuals
  2. Brands
  3. Bitzer Group Manuals
  4. Control Unit
  5. Lodam OLC-K1
  6. Technical manual

Lodam optical level controlling devices

Hide thumbs

1
Table Of Contents 2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
  • Contents
  • Table of Contents
  • Bookmarks

Table of Contents

  • Table of Contents

  • 1 Read this First
    • Reading Instructions

    • User Manual
    • Safety

  • 2 General
  • 3 Definitions
  • 4 Functions
    • Level Monitoring

    • Oil Level Monitoring

    • Level Monitoring in Vessels

    • Red LED Status Light

  • 5 Examples of Application Use
    • Oil Level Monitoring on a Compressor - Direct Start

    • Oil Level Monitoring on a Compressor - Part-Winding

    • Legend for the Schematic Diagrams

    • Connections

  • 6 Technical Data
  • 7 Drawings
    • Olc-D1

    • Olc-K1
  • 8 Standards
    • The Product Is Designed According to the Following Standards

    • The Product Is Tested According to the Following Standards

  • 9 Troulbe Shooting
    • Check the LED on the OLC

  • 10 Index
  • 11 Notes

Advertisem*nt

Quick Links

  • 1 User Manual
  • 2 Oil Level Monitoring
  • 3 Red Led Status Light
  • 4 Olc-K1
  • 5 Troulbe Shooting
  • 6 Check the Led on the Olc
  • Download this manual

Lodam Optical Level Controlling Devices

Technical manual

Version 3.0

OLC-D1, OLC-K1

Table ofContents

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisem*nt

Table of Contents

BITZER GROUP LODAM OLC-K1 TECHNICAL MANUAL Pdf Download (2)

Summary of Contents for Bitzer Group Lodam OLC-K1

  • Page 1 Lodam Optical Level Controlling Devices Technical manual Version 3.0 OLC-D1, OLC-K1...
  • Page 2: Table Of Contents

    Contents 1. Read this first ....................1.1.
  • Page 3 Technical manual OLC-D1, OLC-K1 Page 3...
  • Page 4: Read This First

    1. Read this first 1.1. Reading instructions The contents of this manual are subject to change without notice. Lodam electronics holds the copyright to this user’s The following symbols are used to draw the reader’s manual. The user shall follow any instructions given in this attention to different warning levels.
  • Page 5: General

    Technical manual OLC-D1, OLC-K1 2. General 3. Definitions The OLC-D1 and OLC-K1 are Optical Level Controlling de- Product range vices. The OLC-K1 is for monitoring oil level in compressors Definitions while the OLD-D1 is for controlling levels in vessels. Electro Static Discharge The relay in OLC-K1 is used in the safety chain for the Hardware/electronics compressor and will open and lock-out in case of a failure.
  • Page 6: Functions

    4. Functions If the oil level is too low or there is a failure, the relay will be opened and the LED will signal the failure. • LED Off: Oil level good, no failures The OLC series consists of the two models, OLC-D1 and • LED On: Oil level low OLC-K1.
  • Page 7: Examples Of Application Use

    Technical manual OLC-D1, OLC-K1 5. Examples of application use 5.1. Oil level monitoring on a compressor – direct start Only OLC-K1 Page 7...
  • Page 8: Oil Level Monitoring On A Compressor - Part-Winding

    5.2. Oil level monitoring on a compressor – part-winding Option Option Option Only OLC-K1 Page 8...
  • Page 9: Legend For The Schematic Diagrams

    Technical manual OLC-D1, OLC-K1 5.3. Legend for the schematic diagrams Legend Control unit Control unit of capacity regulation (option) Main fuse Compressor fuse Control circuit fuse Oil level switch High pressure cut-out Low pressure cut-out Fuse of crank case heater F13/F14 Thermal overload motor PW1 / PW2 Signal light “Compressor over temperature fault”...
  • Page 10: Technical Data

    6. Technical data Description OLC-D1 OLC-K1 Supply voltage 115 VAC; ±10%, 50/60 Hz, 3VA / 115 VAC; ±10%, 50/60 Hz, 3VA / 230 VAC; ±10%, 50/60 Hz, 3VA / 230 VAC; ±10%, 50/60 Hz, 3VA 24 VAC/VDC, ±10%, 50/60 Hz, 3VA Max media temperature +120°C +100°C...
  • Page 11: Drawings

    Technical manual OLC-D1, OLC-K1 7. Drawings 7.1. OLC-D1 83,0 to 87,0 (5) 55,5 1,0 (7) 83,0 ±1,0 Ø29 Screw on Cap M24x1 Internal thread Page 11...
  • Page 12: Olc-K1

    7.2. OLC-K1 83,0 to 87,0 (5) 55,5 1,0 (7) 83,0 ±1,0 Ø29 Screw on Cap M24x1 Internal thread Page 12...
  • Page 13: Standards

    Technical manual OLC-D1, OLC-K1 8. Standards 9. Troulbe shooting • Check if there is power to the unit according to specifica- tion. If the power is ok, 8.1. The product is designed • Turn off the power for 5 seconds and see if the relay is according to the following energized after power on again.
  • Page 14: Index

    10. Index Application use 7 Connections 9 Definitions 5 Drawings 11 Functions 6 Legend 9 Safety 4 Standards 13 Technical data 10 Troulbe shooting 13 Page 14...
  • Page 15: Notes

    Technical manual OLC-D1, OLC-K1 11. Notes Page 15...
  • Page 16 As part of the BITZER Group we are backed by one of the world’s leading players in the refrigeration and air conditioning industry. This alliance provides us with extensive network and application knowhow and allows us to stay at the forefront of climate control innovation.

This manual is also suitable for:

Lodam olc-d1

BITZER GROUP LODAM OLC-K1 TECHNICAL MANUAL Pdf Download (2024)
Top Articles
Latest Posts
Article information

Author: Geoffrey Lueilwitz

Last Updated:

Views: 6526

Rating: 5 / 5 (80 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Geoffrey Lueilwitz

Birthday: 1997-03-23

Address: 74183 Thomas Course, Port Micheal, OK 55446-1529

Phone: +13408645881558

Job: Global Representative

Hobby: Sailing, Vehicle restoration, Rowing, Ghost hunting, Scrapbooking, Rugby, Board sports

Introduction: My name is Geoffrey Lueilwitz, I am a zealous, encouraging, sparkling, enchanting, graceful, faithful, nice person who loves writing and wants to share my knowledge and understanding with you.